BP14 - Reduce inlet temperature
| Address: Long Khanh City, Dong Nai Province | |
| Project Summary: A footwear manufacturing enterprise in Dong Nai Province has adopted a solution of inlet temperature reduction to air compressor. | |
| Year of implementation: 2019 | |
|
Status before implementation The inlet temperature of the compressor was quite high. The temperature difference between the compressor inlet at workshop C and in the environment was about 5°C.
Inlet temperature of compressor When the inlet temperature increases by 5°C, the power consumption of the air compressor will increase by 1.5%. |
Result Hot air exhaust pipes have been installed for compressors and dryers. The temperature between the compressor inlet at workshop C and the environment is almost the same.
Installed hot air exhaust for compressor The power consumption of the compressed air system reduces by about 1.7%. |
|
Status before implementation The inlet temperature of the compressor was quite high. The temperature difference between the compressor inlet at workshop C and in the environment was about 5°C.
Inlet temperature of compressor When the inlet temperature increases by 5°C, the power consumption of the air compressor will increase by 1.5%. |
|
|
Result Hot air exhaust pipes have been installed for compressors and dryers. The temperature between the compressor inlet at workshop C and the environment is almost the same.
Installed hot air exhaust for compressor The power consumption of the compressed air system reduces by about 1.7%. |
|
| Result of the project: | |
| Total investment costs: | VND 22 Million |
| Power saving: | 18,227 kWh/ year |
| Cost savings: | VND 10 Million |
| Payback time: | 2.2 years. |